Share
Industrial Technology - Linked-in Industrial Technology - Twitter Industrial Technology - News Feed
Latest Issue
Diary and Events

Virtual Panel Event about Industrial Connectivity

Virtual event

17/05/2021(16:00-17:00)

This 60-minute virtual panel discussion between industry experts will explore the intersection of connectivity (more)

UKIVA Machine Vision Conference

Virtual

15/07/2021

Join us on 15 July 2021 on the MVC Technology Presentation Hub and explore eight online seminar theatres. (more)

PPMA Show 2021

NEC, Birmingham(B40 1NT)

28/09/2021 - 30/09/2021

PPMA Show 2021 will be the UK’s largest ever event dedicated to state-of-the-art processing and (more)

Southern Manufacturing

Farnborough, Hants(GU14 6TQ)

06/10/2021 - 07/10/2021

Southern Manufacturing and Electronics is the most comprehensive annual industrial exhibition in the (more)

Advanced Engineering 2021

NEC Birmingham(B40 1NT)

03/11/2021 - 04/11/2021

Join us in our 12th and most important edition to date, as we invite engineers and management from all (more)

Dispensing tips in wearable device manufacture

Dispensing tips in wearable device manufacture

Peter Swanson, managing director of adhesive specialist Intertronics discusses best practice for dispensing processes in wearable device manufacturing.

Consumer wearables, including smart watches and augmented reality glasses, have captured the imagination of many. One important market for wearable devices is medical and healthcare, where they fulfil a diverse range of functions, such as monitoring patient heart rate, oxygen levels, body temperature and respiratory rate. State of the art wearables have good reliability, precision and are compact.

The comfort, flexibility and connectivity of wearables have been made possible through progress in sensor technology, power management and transmitter technology; these advances in wearable technology require improvements to the production process. One important part of the assembly process is the dispensing of materials like adhesives, silicones, thermally and electrically conductive materials and greases.

Dispensing technology is required for numerous functions when manufacturing a wearable device, such as bonding batteries to the housing, the application of conductive pastes for thermal management, and the sealing, encapsulation and bonding of sensors. Many Micro-Electronic-Mechanical Systems (MEMs) are bonded or encapsulated with a suitable adhesive, and materials are also used to coat or underfill processors, attach and bond RF-modules and seal and bond actuators.

When manufacturing a medical device, it is important that all processes are reliable, consistent and can be validated. The industry requires manufacturers to have a good understanding of process variables, and to control them to create a robust procedure across all dispensing processes. Dispensing processes must be done accurately and repeatably.

Dispensing in action

To achieve the level of precision required, manufacturers can opt for progressive pump technology, as it enables true volumetric dispensing. A progressive cavity pump typically consists of a single-helix metal rotor and a double-helix hole in an elastomeric stator, which forms a sequence of small discrete cavities. These cavities progress through the pump as the rotor is turned, transferring the liquid. The output represents true volumetric dispensing – the amount of material is directly proportional to the number of rotations of the rotor, and is not affected by material viscosity, input pressure or ambient temperature. 

One example technology is the eco-PEN330 preeflow dispenser, which enables the user to dispense volumes as small as 0.001 µl within 1%, 99% of the time – a high level of repeatability and accuracy. It can be used for low or high viscosity materials, with or without filler content.

Dispensing for diabetes management

Medical wearable devices have huge potential for diabetes management. For example, in the US, the digital diabetes management market size has a compound annual growth rate of around 20%. Examples of technologies include continuous glucose monitoring, smart glucose metres and closed loop systems.

One interesting example comes from a client of ViscoTec India, whose engineers created a closed loop system, consisting of a skin patch that measures blood glucose levels, a device that calculates the required insulin dose, and a smart pump that injects the dose. During the production process, the manufacturer required the precise dispensing of 0.7 microlitres of grease into a gearbox component of the electric motor in the insulin pump. These precise requirements were fulfilled with a preeflow eco-PEN330.

Automating the process

In most wearable production processes, adhesive dispensing is automated to achieve a high degree of repeatability. Once the dispensing technology has been selected, manufacturers can repeat the application of materials with positional accuracy by incorporating a robot or other form of automation. Medical device manufacturers have several options to mechanise the process, which include rotary tables or simple 3-axis benchtop robots, usually at modest cost, right up to multi-axis robots with vision-based control and feedback.

As well as delivering productivity benefits from their speed, consistency and ability to run continuously, automation can enable results not possible manually. They can deliver rapid return on investment, particularly when precision and accuracy-based productivity gains are taken into consideration.

The use of wearable technology in consumer and healthcare applications is now widespread. To produce a compact, reliable and precise device that meets rigorous industry standards, manufacturers require a robust dispensing process. Working with an experienced adhesives and dispensing equipment supplier can help you to invest in suitable technology.